System Overview

A PU Cleanroom Panel bonds two coated-steel facings to a rigid polyurethane (PU) foam core — a high-insulation, airtight cleanroom wall and ceiling panel made to a ≤ 2 mm/2 m flatness tolerance. 

Product Details

PU Cleanroom Panel — High-Insulation Polyurethane Sandwich Panel

The PU Cleanroom Panel combines coated-steel skins with a rigid polyurethane core. Its closed-cell construction provides low thermal conductivity, airtight sealing, low weight and ≤ 2 mm/2 m flatness for temperature-controlled rooms.

Get a Quick Quote & Spec Sheet → Chat on WhatsApp Reply ≤ 24 h · Free spec & quotation

What Is a PU Cleanroom Panel?

A PU cleanroom panel uses color-coated steel facings around rigid polyurethane foam. The closed-cell core provides high insulation, a strong bond and low weight, while the steel surface is anti-static, wipe-clean and corrosion-resistant.

PU suits cold rooms and controlled environments where insulation and sealing lead. Choose PIR for a higher B1 fire rating, or rock wool and MgO rock wool when A-grade non-combustibility is required.

Part of Wonclean's cleanroom sandwich panel family, the PU panel pairs with matching ceiling systems and cleanroom doors and windows for a fully sealed, flush cleanroom wall system.

PU cleanroom panel - perspective view with polyurethane foam core and edge joint Polyurethane cleanroom sandwich panel - tongue-and-groove edge profile and PU core PU cleanroom wall panel - flush front face with inspection port

Panel Anatomy — Layer by Layer

① Outer coated-steel skin — 0.4–0.6 mm, anti-static, corrosion-resistant
② Foamed-in adhesive bond (self-bonding PU)
③ Rigid polyurethane (PU) closed-cell core — 38–45 kg/m³
④ Foamed-in adhesive bond (self-bonding PU)
⑤ Inner coated-steel skin — flush, wipe-clean cleanroom surface
Lowest thermal conductivity Closed-cell, airtight Strong facing bond Lightweight

Core Features

✔ Best-in-class thermal insulation ✔ Airtight closed-cell core ✔ Moisture & vapour barrier ✔ Lightweight, strong bond ✔ Fire class B1 / B2 ✔ Anti-static, no dust generation ✔ Flatness ≤ 2 mm/2 m ✔ Custom length, thickness & color

Technical Specifications


Panel thickness 50 mm standard; 75 / 100 mm and other thicknesses fully customizable
Effective width 1150 mm standard (1180 mm overall); 980 mm optional
Panel length Cut-to-size, typically up to 6000 mm per panel; longer on request
Facing (steel) Top-brand pre-painted / galvanized steel 0.4–0.6 mm; stainless steel option
Core Rigid polyurethane (PU/PUR) closed-cell foam, density 38–45 kg/m³
Thermal conductivity λ ≈ 0.022–0.024 W/(m·K) — best in range
Fire rating Fire class B1 / B2 by formulation; for A-grade choose rock wool / MgO
Weight Lightweight ≈ 11–14 kg/m² depending on facing & thickness
Flatness tolerance ≤ 2 mm / 2 m for tight, gap-minimised joints
Joint system Tongue-and-groove, cam-lock or aluminium H / C connectors
Standards / lead time EN 13501-1 · ASTM E84 · BS 476 · ISO 9001 · CE · China / Shanghai · ~10–25 days

Standard configurations shown; all dimensions, steel gauge, core density, color and certificates are tailored per project — request the full datasheet & test reports.

PU vs PIR vs Rock Wool — Pick the Core


Core Insulation Fire class Best for
PU (this panel) Best (λ ≈ 0.022) B1 / B2 Cold rooms, controlled temperature
PIR Excellent (λ ≈ 0.023) B1 (better) Insulation + improved fire safety
Rock wool Good (λ ≈ 0.040) A-grade Fire-rated walls, acoustics

Where PU Panels Are Used

Cold rooms & cold storage
Low-temperature rooms requiring strong insulation.

Food & cold-chain
Processing and chilled storage areas.
Temperature-controlled cleanrooms
Pharma, biotech and humidity-sensitive processes.
Insulated partitions & ceilings
Lightweight insulated partitions and ceilings in controlled plants.

From Spec to Site — 4 Steps

01
Specify
Confirm thickness, gauge, color, temperature and rating.

02
Manufacture
Production targets ≤ 2 mm/2 m flatness.
03
Pack & ship
Panels ship protected and crated.
04
Install
Fast sealed installation with technical support.

Expert FAQ on PU Cleanroom Panels

When should I choose PU over PIR or rock wool?

Choose PU when thermal insulation and sealing are the top priority — cold rooms, cold-chain and controlled-temperature areas — as it has the lowest thermal conductivity. If you need a higher fire rating with similar insulation, the PIR panel (B1) is better; for A-grade non-combustible walls choose rock wool.

What is the fire rating of a PU panel?

PU cores are available in B1 or B2 flame-retardant grades, with third-party reports. Use mineral cores where A-grade is mandatory.

How good is the thermal insulation?

With λ around 0.022 W/(m·K), PU achieves strong insulation at lower thickness and helps reduce cooling energy.

Does the panel prevent condensation in cold rooms?

Closed-cell foam and sealed joints control vapour, air leakage and condensation in chilled rooms.

Which facing, color and flatness can I expect?

Pre-painted or stainless steel facings are available in matched RAL or custom colors, targeting ≤ 2 mm/2 m flatness.

What are the lead time and minimum order?

Typical lead time is 10–15 days for samples or small orders and 20–25 days for a full container, subject to specification.

Ready to Spec Your PU Cleanroom Panels?

Send thickness, facing, color, target temperature, fire class and quantity for a schedule, reports and quote. Typical reply within 24 hours.

Email: Info@wonclean.com Phone: +86 136 7197 9988 Allen WhatsApp: +86 159 5093 8878 Joy Available 24/7

Hot Tags: clean room panel supplier · cleanroom wall panels · cleanroom panel manufacturer · PIR cleanroom panel · cleanroom sandwich panel · clean room partition

Leave A Message

For more product details and new products, please leave a message.We'll reply quickly!

If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!